1. The communication adopts the HTTP protocol.
2. The permission management adopts network authentication.
3. Real time reporting and interactive response methods are used to ensure the timeliness and reliability of data collection.
4. Supports local, real-time, and real-time+local working modes, suitable for different scene requirements.
5. The maximum number of permissions for each gate area is 120000, and the maximum number of offline records is 60000.
Overall dimensions 330mm x 230mm x 70mm
The total weight of the machine is 2.847kg
Working voltage 12V DC
Working current 2A
Main control chip 32-bit ARM Cortex-M4, clock frequency 168MHz, supports FPU (Floating Point Unit) and DSP instructions
512K FLASH and 192K SRAM memory.